Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Rev. Hosp. Ital. B. Aires (2004) ; 43(2): 93-97, jun. 2023. ilus, tab
Article in Spanish | LILACS, UNISALUD, BINACIS | ID: biblio-1510690

ABSTRACT

La rotura traumática, simultánea y bilateral del tendón cuadricipital es una lesión infrecuente, generalmente asociada a otras enfermedades sistémicas tales como insuficiencia renal o trastornos endocrinos. Presentamos el caso de un varón sano y atleta de 38 años que sufrió esta lesión mientras realizaba una sentadilla en el gimnasio. (AU)


The traumatic bilateral and simultaneous quadriceps tendon rupture is a rare injury, usually associated with other systemic diseases such as renal insufficiency or endocrine disorders. We present the case of a 38-year-old healthy male athlete who sustained this injury while performing a squat at the gym. (AU)


Subject(s)
Humans , Male , Adult , Rupture/diagnostic imaging , Tendon Injuries/diagnostic imaging , Quadriceps Muscle/injuries , Quadriceps Muscle/diagnostic imaging , Rupture/surgery , Tendon Injuries/surgery , Magnetic Resonance Spectroscopy , Radiography , Ultrasonography , Quadriceps Muscle/surgery , Knee/surgery , Knee/diagnostic imaging
2.
Int. j. morphol ; 41(2): 640-645, abr. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1440314

ABSTRACT

SUMMARY: Skeletal muscles play a fundamental role in people's lives and their evaluation provides significant information on health. Different tools have been used to evaluate muscle mass, and the evaluation of muscle thickness (MT) using ultrasound has been included as an alternative, which can be performed with the probe in different positions; however, these could present differences. The objectives of this study were to determine whether there are differences in the measurement of MT in the vastus lateralis (VL) muscle using the probe in the longitudinal or transverse position, and to determine its association with the lean mass of the lower limbs. The results indicated no significant differences between MT measurements with the probe in the longitudinal and transverse positions (p =0.084). However, when associating these measurements with lower limb lean mass, it was found that transverse measurements had a strong association (r =0.547; p < 0.001), while longitudinal measurements had a moderate association (r =0.351; p =0.007). This suggests that measurements with the probe positioned transversely to measure the MT would be the best option. Therefore, it could be useful as an indicator of lower limb lean mass in the absence of tools, such as bioelectrical bioimpedance or magnetic nuclear resonance.


El músculo esquelético cumple un rol fundamental en la vida de las personas, y su evaluación entrega mucha información de la salud. Se han utilizado diferentes herramientas para evaluar la masa muscular, y el último tiempo se ha incluido la evaluación del grosor muscular (MT) a través de la ecografía como una alternativa para estimarla, las cuales se pueden realizar con la sonda en distintas posiciones, sin embargo, estas podrían presentar diferencias. Los objetivos del estudio fueron determinar si existen diferencias en la medición de MT en el músculo vasto lateral (VL) utilizando la sonda en posición longitudinal o transversal y determinar su asociación con la masa magra de los miembros inferiores. Los resultados indican que no existen diferencias significativas entre las mediciones de MT con la sonda en posición longitudinal y transversal (valor p: 0.084). Sin embargo, al asociar estas mediciones con la masa magra de los miembros inferiores, se encontró que las mediciones transversales poseen una asociación fuerte (r: 0.547; valor p < 0.001), mientras que las mediciones longitudinales presentan una asociación moderada (r: 0.351; valor p: 0.007). Esto sugiere que las mediciones con la sonda posicionada transversal para medir MT serían la mejor opción. Por lo tanto, podría ser de utilidad como un indicador de masa magra de los miembros inferiores en caso de no contar con herramientas como la bioimpedancia bioeléctrica o resonancia nuclear magnética.


Subject(s)
Humans , Male , Female , Adult , Adipose Tissue/diagnostic imaging , Quadriceps Muscle/diagnostic imaging , Ultrasonics , Anthropometry , Adipose Tissue/anatomy & histology , Muscle, Skeletal , Quadriceps Muscle/anatomy & histology , Patient Positioning
3.
Journal of Peking University(Health Sciences) ; (6): 843-849, 2021.
Article in Chinese | WPRIM | ID: wpr-942263

ABSTRACT

OBJECTIVE@#To investigate the correlation between the quadriceps cross-sectional area (CSA) and quadriceps muscle volume (QMV) at different horizontal levels from the upper edge of the patella, and to determine the best observation position.@*METHODS@#Thigh magnetic resonance imaging (MRI) images of 22 Chinese young men [age: (29±6) years] with anterior cruciate ligament (ACL) rupture were examined. The CSA was measured at 18, 15, and 12 cm above the upper edge of the pate-lla (denoted by CSA-18, CSA-15 and CSA-12 respectively), and the QMV and CSA were determined by semiautomatic segmentation. A curve model was established to estimate QMV. Bland-Altman analysis was performed to determine the confidence limits of the volumes.@*RESULTS@#On the unaffected side, the mean QMV was (1 944.45±323.77) cm3. The quadriceps CSA at the upper edge of the patella at 18, 15, and 12 cm was (80.80±12.16) cm2, (77.53±12.03) cm2, and (72.68±10.51) cm2, respectively. The coefficients of determination (R2), ascertained using curve estimation models, for the 3 positions were 0.819, 0.755, and 0.684 (P < 0.001), and the standard deviations of the volume estimated value (SEE) were 7.4%, 8.7%, and 9.8%. The fitting equations of the three horizontal positions were all good, but the fitting degree of CSA-18 was the highest. The Bland-Altman scatter plot showed that the arithmetic means of the QMV at 18, 15 and 12 cm from the upper edge of the patella 0.8 cm3, -1.1 cm3, and 0.9 cm3 and 95% limits of agreement (LoA) were (-268.8, 270.5), (-315.2, 313.1), and (-355.7, 357.5), respectively. The estimated QMV was in good agreement with the measured value. The difference between the estimated CSA-18 and measured values was the smallest. The results on the affected side were consistent.@*CONCLUSION@#The correlation between QMV and CSA in the young men with the upper edge of patella as baseline was reliable and consistent. Among them, CSA-18 had the highest correlation with the QMV. However, different observation sites could be selected for different injuries of the quadriceps.


Subject(s)
Adult , Humans , Male , Young Adult , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction , Magnetic Resonance Imaging , Patella , Quadriceps Muscle/diagnostic imaging
5.
Clinics ; 75: e1768, 2020. tab, graf
Article in English | LILACS | ID: biblio-1133466

ABSTRACT

OBJECTIVES: Menopause marks the end of women's reproductive period and can lead to sarcopenia and osteoporosis (OP), increasing the risk of falls and fractures. The aim of this study is to evaluate the influence of normal and low bone mineral density (BMD) on muscular activity, observed through inflammatory edema when mapping using magnetic resonance imaging (MRI) on the quadriceps muscle of postmenopausal women. METHODS: This was a cross-sectional study involving 16 older women, who were divided into two groups: osteoporosis group (OG), older women with OP, and control group (CG), older women without OP. The groups were evaluated in terms of nuclear MRI exam before and after carrying out fatigue protocol exercises using an isokinetic dynamometer and squatting exercises. RESULTS: The results of the present study showed that in intragroup comparisons, for both groups, there was a significant increase (p<0.05) in the T2 signal of the nuclear MRI in the quadriceps muscle after carrying out exercises using both thighs. In the intergroup comparison, no statistically significant difference was observed between the OG and CG, pre- (p=0.343) and postexercise (p=0.874). CONCLUSION: The acute muscular activation of the quadriceps evaluated by T2 mapping on nuclear MRI equipment is equal in women with and without OP in the postmenopausal phase. BMD did not interfere with muscle response to exercise when muscle fatigue was reached.


Subject(s)
Humans , Female , Aged , Magnetic Resonance Imaging/methods , Postmenopause , Quadriceps Muscle/diagnostic imaging , Absorptiometry, Photon , Bone Density , Osteoporosis, Postmenopausal , Cross-Sectional Studies , Quadriceps Muscle/physiopathology
6.
Rev. bras. ter. intensiva ; 31(4): 464-473, out.-dez. 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1058043

ABSTRACT

RESUMO Objetivo: Avaliar a segurança e a viabilidade da avaliação por ultrassonografia do quadríceps no pronto-socorro, e avaliar a confiabilidade intra e entre avaliadores para aquisição e análise de imagens de ultrassonografia da espessura e da ecogenicidade muscular em pacientes críticos de trauma. Métodos: Estudo de precisão diagnóstica realizado por meio de exames e avaliações feitos por profissionais de saúde com diferentes níveis de especialização. Dois examinadores (um especialista e um novato) procederam à aquisição de imagens de ultrassom de dez pacientes. Um avaliador experiente, cego quanto aos examinadores, quantificou as imagens obtidas. Em um grupo à parte de dez pacientes, dois avaliadores (um especialista e um novato) quantificaram a espessura do músculo quadríceps femoral, assim como sua ecogenicidade (métodos quadrado ou tracejado) em imagens adquiridas por um examinador. Resultados: Identificou-se excelente confiabilidade quanto à aquisição da imagem e à sua análise (coeficientes de correlação intraclasses > 0,987; p < 0,001). O erro padrão dos valores de mensurações variou de 0,01 a 0,06 cm, para a espessura muscular, e de 0,75 a 2,04 unidades arbitrárias, para ecogenicidade muscular. Os valores de ecogenicidade foram mais elevados quando se utilizou o método quadrado do que quando se utilizou o método tracejado (p = 0,003). Conclusão: A ultrassonografia é um método seguro, viável e confiável para avaliação muscular em pacientes críticos de trauma, independentemente do nível de especialização do avaliador.


ABSTRACT Objective: To evaluate the safety and feasibility of the ultrasound assessment of quadriceps in the emergency setting. To assess the intra- and interrater reliability for the acquisition and analysis of ultrasound images of muscle thickness and echogenicity in critically ill trauma patients between health professionals with different levels of expertise. Methods: Diagnostic accuracy study. Two examiners (expert and novice) acquired ultrasound images from ten patients; an experienced, blinded analyst quantified the images. In a separate group of ten patients, two analysts (expert and novice) quantified quadriceps muscle thickness and echogenicity (square or trace method) from images acquired by one examiner. Results: Excellent reliability was found for image acquisition and analysis (intraclass correlation coefficients > 0.987; p < 0.001). The standard error of the measurement values ranged from 0.01 - 0.06cm for muscle thickness and from 0.75 - 2.04 arbitrary units for muscle echogenicity. The coefficients of variation were < 6% for thickness and echogenicity. The echogenicity values were higher when using the square technique than when using the tracing technique (p = 0.003). Conclusion: Ultrasound is safe, feasible, and reliable for muscle assessment in critically ill trauma patients, regardless of the assessor's level of expertise.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Wounds and Injuries/complications , Ultrasonography/methods , Feasibility Studies , Reproducibility of Results , Ultrasonography/adverse effects , Critical Illness , Quadriceps Muscle/diagnostic imaging , Middle Aged
7.
Fisioter. Pesqui. (Online) ; 26(3): 227-234, jul.-set. 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1039884

ABSTRACT

RESUMO O objetivo deste estudo foi avaliar os efeitos do exercício passivo precoce em cicloergômetro na espessura muscular (EM) do quadríceps femoral (EMQ) de pacientes críticos admitidos em uma Unidade de Terapia Intensiva (UTI) de um hospital universitário terciário. O método utilizado foi um estudo-piloto randomizado controlado conduzido em uma amostra de 24 pacientes (51±18,11 anos, 16 do sexo masculino), com 24 a 48 horas de ventilação mecânica (VM), aleatoriamente divididos em dois grupos: grupo-controle (n=12), que recebeu a fisioterapia convencional; e grupo-intervenção (n=12), que recebeu o exercício passivo em cicloergômetro, uma vez ao dia, durante o período de sete dias do protocolo, em adição à fisioterapia convencional. A EMQ foi mensurada através da ultrassonografia. A primeira medida ultrassonográfica foi realizada entre as primeiras 48 horas de VM e a segunda ao término do protocolo. Não houve diferenças significativas na EMQ esquerda (27,29±5,86mm vs. 25,95±10,89mm; p=0,558) e direita (24,96±5,59mm vs 25,9±9,21mm; p=0,682) do grupo-controle e na EMQ esquerda (27,2±7,38mm vs 29,57±7,89mm; p=0,299) e direita (26,67±8,16mm vs 28,65±8,04mm; p=0,381) do grupo-intervenção. Na comparação entre os grupos, não houve alterações significativas em relação à EMQ esquerda (3,61±1,07mm; p=0,248) e a EMQ direita (2,75±0,85mm; p=0,738). Os resultados deste estudo-piloto demonstraram que a aplicação precoce do exercício passivo em cicloergômetro não promoveu mudanças significativas na espessura da camada muscular avaliada. No entanto, nossos achados sinalizam que a fisioterapia convencional foi capaz de preservar a EMQ de pacientes críticos admitidos em UTI.


RESUMEN El presente estudio tuvo como objetivo evaluar los efectos del ejercicio pasivo precoz en cicloergómetro en el espesor muscular (EM) del cuádriceps femoral (EMC) de pacientes críticos ingresados en una Unidad de Cuidados Intensivos (UCI) de un hospital universitario terciario. Se utilizó como método un estudio piloto aleatorizado controlado con una muestra de 24 pacientes (51±18,11 años, 16 varones), con 24 a 48 horas de ventilación mecánica (VM), quienes fueron divididos aleatoriamente en dos grupos: grupo de control (n=12), que recibió fisioterapia convencional; y grupo intervención (n=12), que recibió el ejercicio pasivo en cicloergómetro una vez al día durante el período de protocolo de siete días, además de la fisioterapia convencional. El EMC se midió por ecografía. La primera medición ecográfica se realizó entre las primeras 48 horas de VM, y la segunda al final del protocolo. No hubo diferencias significativas en el EMC izquierdo (27,29±5,86 mm vs. 25,95±10,89mm; p=0,558) y derecho (24,96±5,59mm vs 25,9±9,21mm; p=0,682) del grupo de control; y en el EMC izquierdo (27,2±7,38mm vs 29,57±7,89mm; p=0,299) y derecho (26,67±8,16mm vs 28,65±8,04mm; p=0,381) del grupo intervención. En la comparación entre grupos, no hubo cambios significativos en el EMC izquierdo (3,61±1,07 mm; p=0,248) y en el EMC derecho (2,75±0,85 mm, p=0,738). Los resultados de este estudio piloto demostraron que la aplicación precoz del ejercicio pasivo en cicloergómetro no promovió cambios significativos en el espesor de la capa muscular evaluada. Sin embargo, nuestros hallazgos indican que la fisioterapia convencional pudo preservar el EMC de pacientes críticos ingresados en la UCI.


ABSTRACT The objective of this study was to evaluate the effects of early passive cycling exercise on quadriceps femoris thickness (QFT) in critically ill patients admitted in the intensive care unit (ICU) of a tertiary care university hospital. A controlled randomized pilot study was conducted with a sample of 24 patients (51±18.11 years, 16 male), on mechanical ventilation (MV) from 24 to 48 hours, who were randomly divided into two groups: control group (n=12), receiving conventional physical therapy; and an intervention one (n=12), receiving passive cycle ergometer, once a day, throughout seven days of protocol, in addition to conventional physical therapy. The QFT was measured by ultrasonography. The first ultrasonographic measurement was performed within 48 hours after the start of MV, and the second at the end of the protocol. There were no significant differences in QFT of the left (27,29±5,86mm vs 25,95±10,89mm; p=0,558) and right (24,96±5,59mm vs 25,9±9,21mm; p=0,682) in the control group, and in QFT of the left (27,2±7,38mm vs 29,57±7,89mm; p=0,299) and right (26,67±8,16mm vs 28,65±8,04mm; p=0,381) in the intervention group. There were no significant between-groups differences for left QFT (3,61±1,07mm; p=0,248) and right QFT (2,75±0,85mm; p=0,738). The results of this pilot study demonstrate that application of early passive cycle ergometer exercises has not significantly change the muscle layer thickness. However, our findings indicate that conventional physical therapy is able to preserve the quadriceps femoris thickness in critically ill patients admitted in ICU.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Early Ambulation , Quadriceps Muscle/anatomy & histology , Exercise Therapy/methods , Muscular Atrophy/prevention & control , Pilot Projects , Ultrasonography , Physical Therapy Modalities/instrumentation , Quadriceps Muscle/diagnostic imaging , Intensive Care Units
8.
Rev. Assoc. Med. Bras. (1992) ; 65(7): 952-958, July 2019. tab, graf
Article in English | LILACS | ID: biblio-1013011

ABSTRACT

SUMMARY PURPOSE In this prospective observational study, we aimed to investigate the role of the maximum compressed (MC) and uncompressed (UC) thickness of the quadriceps femoris muscle (QFMT) measured by ultrasonography (USG) in the detection of nutritional risk in intensive care patients (ICPs) with different volume status. METHODS 55 patients were included. Right, left, and total ucQFMT and mcQFMT measurements were obtained by a standard USG device within the first 48 hours after ICU admission. Clinical examination and the USG device were used to determine the volume status of the patients. SOFA, APACHE II, modified NUTRIC scores, and demographic data were collected. RESULTS There was a significant difference between the nutritional risk of patients in terms of left, right, and total mcQFMT measurements (p=0.025, p=0.039; p=0.028, respectively), mechanical ventilation requirement (p=0.014), presence of infection (p=0.019), and sepsis (p=0.006). There was no significant difference between different volume statuses in terms of mcQFMT measurements. In the multi-variance analysis, mcQFMT measurements were found to be independently associated with high nutritional risk (p=0.019, Exp(B)=0.256, 95%CI=0.082-0.800 for modified NUTRIC score ≥ 5), and higher nutritional risk (p=0.009, Exp(B)=0.144, 95%CI=0.033-0.620 for modified NUTRIC score ≥ 6). a Total mcQFMT value below 1.36 cm was a predictor for higher nutritional risk with 79% sensitivity and 70% specificity (AUC=0.749, p=0.002, likelihood ratio=2.04). CONCLUSION Ultrasonographic measurement of total mcQFMT can be used as a novel nutritional risk assessment parameter in medical ICPs with different volume statuses. Thus, patients who could benefit from aggressive nutritional therapy can be easily identified in these patient groups.


RESUMO OBJETIVO Neste estudo observacional prospectivo, objetivamos investigar o papel da espessura do músculo quadríceps femoral (QFMT) comprimido (mc) e não comprimido (uc) medida pela ultrassonografia (USG) na detecção do risco nutricional em pacientes de terapia intensiva (ICPs) com status de volume diferente. MÉTODOS Cinquenta e cinco pacientes foram incluídos. As medidas direita, esquerda e total de ucQFMT e mcQFMT foram obtidas por um dispositivo USG padrão nas primeiras 48 horas após a admissão na UTI. O exame clínico e o dispositivo USG foram usados para determinar o status volumétrico dos pacientes. Sofa, Apache II, escores Nutric modificados e dados demográficos foram coletados. RESULTADOS Houve diferença significativa entre o risco nutricional dos pacientes em termos de medidas da QTFMT esquerda, direita e total (p=0,025, p=0,039; p=0,028, respectivamente), necessidade de ventilação mecânica (p=0,014), presença de infecção (p=0,019) e sepse (p=0,006). Não houve diferença significativa entre os diferentes status de volume em termos de medidas de mcQFMT. Na análise de variância múltipla, verificou-se que as medidas da FCFMT estavam independentemente associadas a alto risco nutricional (p=0,019, Exp (B)=0,256, 95%CI=0,082-0,800 para escore Nutric modificado ≥ 5) e maior risco nutricional (p=0,009, Exp (B)=0,144, 95%CI=0,033-0,620 para o escore Nutric modificado ≥ 6). O valor total de mcQFMT abaixo de 1,36 cm foi um preditor de maior risco nutricional com sensibilidade de 79% e especificidade de 70% (ASC=0,749, p=0,002, razão de verossimilhança = 2,04). CONCLUSÃO A medida ultrassonográfica do mcQFMT total pode ser usada como um novo parâmetro de avaliação de risco nutricional em ICPs médicas com diferentes status de volume. Assim, pacientes que podem se beneficiar de uma terapia nutricional agressiva podem ser facilmente identificados nesses grupos de pacientes.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Nutritional Status/physiology , Ultrasonography/methods , Quadriceps Muscle/pathology , Quadriceps Muscle/diagnostic imaging , Reference Values , Respiration, Artificial/adverse effects , Logistic Models , Nutrition Assessment , Prospective Studies , Sensitivity and Specificity , Critical Illness , Risk Assessment , APACHE , Malnutrition/physiopathology , Malnutrition/pathology , Malnutrition/diagnostic imaging , Nutrition Therapy/methods , Quadriceps Muscle/physiopathology , Intensive Care Units , Length of Stay , Middle Aged
9.
Rev. Assoc. Med. Bras. (1992) ; 65(2): 165-170, Feb. 2019. tab, graf
Article in English | LILACS | ID: biblio-990316

ABSTRACT

SUMMARY OBJECTIVE: With high-resolution real-time ultrasonography we investigated the muscle architectural parameters of vastus lateralis in healthy volunteers. PURPOSES: We determined the reproducibility and validity of ultrasonography and the role of the ultrasonographer in assessing muscle architecture. We proposed the most appropriate clinical parameters for objective measurements and an ultrasound protocol of muscle architecture. METHODS: We conducted an intraobserver and interobserver study. We investigated 21 healthy male volunteers. The subjects were independently evaluated by four different operators using high-resolution real-time ultrasonography. To assess the reproducibility of ultrasound examinations, four operators repeated measurements using the same ultrasound device. Muscle thickness, muscle volume, muscle fiber pennation angle, and subcutaneous adiposity of the vastus lateralis muscle were measured. RESULTS: Intra-observer (ICC 0.92-0.97), interobserver (ICC 0.78-0.92) reproducibility was good to excellent for all measurements. CONCLUSION: Simple, reproducible, non-invasive ultrasound measurements of muscle structure easily demonstrated differences in muscle morphology. With a protocol and with objective and repeatable measurements, sonographers from different backgrounds could obtain an objective measurement of ultrasound images with little differences and low variability in results, thanks to the upgrading of diagnostic ultrasound imaging and their clinical skills.


RESUMO OBJETIVO: Nós utilizamos ultrassonografia de alta resolução em tempo real para investigar os parâmetros da arquitetura muscular do vasto lateral em voluntários saudáveis. PROPÓSITO: Nós determinamos da reproduzibilidade e validade da ultrassonografia e o papel do ultrassonografista na avaliação da arquitetura muscular. Nós propomos os parâmetros clínicos mais apropriados para uma medição objetiva e um protocolo de ultrassonografia para arquitetura muscular. MÉTODOS: Nós conduzimos um estudo intra-observador e inter-observador. Investigamos 21 voluntários saudáveis do sexo masculino. Os participantes foram avaliados de forma independente por quatro operadores diferentes usando ultrassonografia de alta-resolução em tempo real. Para avaliar a reprodutibilidade dos exames de ultrassonografia, quatro operadores repetiram as medições usando o mesmo equipamento de ultrassonografia. A espessura e o volume do músculo, o ângulo de penação da fibra muscular, adiposidade subcutânea do músculo vasto lateral foram medidos. RESULTADOS: A reprodutibilidade intra-observador (ICC 0,92-0,97) e inter-observador (ICC 0,78-0,92) foi boa a excelente para todas as medições. CONCLUSÃO: Medições de ultrassonografia simples, reprodutíveis e não-invasivas da estrutura muscular demostraram facilmente as diferenças na morfologia muscular. Seguindo um protocolo e com medições objetivas e reproduzíveis, ultrassonografistas com diferentes formações e experiências podem conseguir uma medição objetiva de imagens de ultrassonografia com poucas diferenças e pouca variação nos resultados graças à melhoria da qualidade nos exames de diagnóstico por imagem de ultrassonografia e das habilidades clínicas.


Subject(s)
Humans , Male , Adult , Ultrasonography/standards , Quadriceps Muscle/diagnostic imaging , Observer Variation , Reproducibility of Results , Ultrasonography/methods
10.
Clinics ; 74: e727, 2019. tab, graf
Article in English | LILACS | ID: biblio-1001835

ABSTRACT

OBJECTIVES: To compare the ultrasonographic findings of entheses in ankylosing spondylitis (AS) patients with those of healthy control individuals and to assess the ability of ultrasound (US) to identify aspects related to the disease. METHODS: A cross-sectional study involving 50 patients with AS and 30 healthy controls was performed. Clinical assessment included the use of a visual analog scale for pain, assessment of swelling of the enthesis, global assessments for patients and physician, use of a disease activity index, mobility and dysfunctional indices, erythrocyte sedimentation rate and clinical enthesitis index. US was performed for the following entheses by two experienced musculoskeletal radiologists: brachial triceps, distal quadriceps, proximal and distal patellar tendons, calcaneal tendon, and plantar fascia; the total and subitems of the Madrid Sonographic Enthesitis Index were used for evaluations. RESULTS: Comparison between groups showed a statistically significant difference with worse scores in AS patients, with bone erosion of the calcaneal enthesis and bone erosion and thickening of the plantar fascia. The odds ratio for thickening of the plantar fascia in the AS group was 3.47, according to logistic regression analysis. The AS group also had worse scores regarding the presence of calcification in the quadriceps enthesis, with a fivefold increased risk. CONCLUSION: US analysis showed that only entheses of the foot and quadriceps were able to differentiate AS patients from healthy individuals.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Spondylitis, Ankylosing/diagnostic imaging , Calcaneus/diagnostic imaging , Quadriceps Muscle/diagnostic imaging , Achilles Tendon/diagnostic imaging , Severity of Illness Index , Observer Variation , Cross-Sectional Studies , Ultrasonography/methods , Patellar Ligament/diagnostic imaging , Diagnosis, Differential , Fascia/diagnostic imaging
11.
Clinics ; 73: e392, 2018. tab, graf
Article in English | LILACS | ID: biblio-974937

ABSTRACT

OBJECTIVES: We evaluated the validity and reliability of ultrasonography measurement of rectus femoris cross-sectional area compared to computed tomography in patients in pre-dialysis chronic kidney disease and analyzed the association between these measurements and the diagnosis of sarcopenia. METHODS: One hundred patients with nondialysis chronic kidney disease were evaluated. Sarcopenia was defined using the criteria of the Foundation for the National Institutes of Health Sarcopenia Project (FNIH). The rectus femoris cross-sectional area was evaluated using ultrasonography and computed tomography. RESULTS: The prevalence of sarcopenia was 29% according to the FNIH criteria. The difference in mean rectus femoris cross-sectional area by ultrasonography and computed tomography was 3.97 mm, with a strong correlation between the two methods (p<0.001). Bland-Altman plot analysis showed good agreement between computed tomography and ultrasonography. Rectus femoris cross-sectional area was significantly correlated with muscle strength (r=0.300, p=0.002), lean body mass in the upper limbs (r=0.286, p=0.004), and lean body mass in the lower limbs (r=0.271, p=0.006). The prevalence of sarcopenia was 12% (n=12) based on the definition of low muscle mass according to ultrasonography of the rectus femoris cross-sectional area. CONCLUSION: Ultrasonography was demonstrated to be a valid and reliable method for evaluating the rectus femoris cross-sectional area in patients in pre-dialysis chronic kidney disease.


Subject(s)
Humans , Male , Female , Aged , Quadriceps Muscle/diagnostic imaging , Renal Insufficiency, Chronic/complications , Sarcopenia/diagnostic imaging , Tomography, X-Ray Computed , Cross-Sectional Studies , Reproducibility of Results , Ultrasonography , Sarcopenia/complications
12.
Rev. bras. ter. intensiva ; 29(4): 476-480, out.-dez. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-899543

ABSTRACT

RESUMO Objetivo: Avaliar a intra e interconfiabilidade, e a facilidade de medir a espessura muscular do quadríceps, usando ultrassom à beira do leito. Métodos: Trata-se de um estudo prospectivo, observacional. A avaliação da espessura muscular do quadríceps foi realizada em dois pontos de referência e quantificada com ultrassom portátil em modo B em dois voluntários saudáveis. Para padronização das medidas e validação das coletas das imagens, foi realizada capacitação da equipe por meio de treinamentos com aulas teóricas e práticas, com carga horária de 6 horas. Resultados: Foram examinadas 112 imagens pelo treinador e comparadas com os alunos. A correlação de Person encontrou excelente relação entre o treinador e todos os alunos (R2 > 0,90). A melhor associação foi entre o treinador e os nutricionistas (R2: 0,99; p < 0,001), e a pior, entre o treinador e alunos médicos (R2: 0,92; p < 0,001). Quanto à comparação de Bland-Altman, a maior porcentagem de erro encontrada entre treinador e alunos foi de 5,12% (IC95% 3,64 - 12,37) e a menor, 1,01% (IC95% 0,72 - 2,58); o maior viés dos valores descrito foi -0,12 ± 0,19, e o menor, -0,01 ± 0,04. Conclusão: Os dados analisados mostraram boa correlação entre as medidas feitas pelo instrutor e alunos, mostrando que o ultrassom de músculo quadríceps é uma ferramenta viável e de fácil aplicabilidade.


ABSTRACT Objective: To evaluate the intra- and inter-reliability and the ease of measuring the quadriceps muscle thickness using bedside ultrasound. Methods: This is a prospective, observational study. The assessment of quadriceps muscle thickness was performed at two reference points and was quantified using portable B-mode ultrasound in two healthy volunteers. For standardization of measurements and validation of image collections, the team was trained through theoretical and practical classes, with a 6-hour workload. Results: A total of 112 images were examined by the coach and compared with the trainees. Pearson's correlation analysis found an excellent relationship between the coach and all trainees (R2 > 0.90). The best association was between the coach and the dietitians (R2: 0.99; p < 0.001), and the worst association was between the coach and the medical trainees (R2: 0.92; p < 0.001). In the Bland-Altman comparison, the highest error rate found between coach and trainees was 5.12% (95% confidence interval [CI] 3.64-12.37), and the lowest was 1.01% (95%CI 0.72 - 2.58); the highest bias of the values described was -0.12 ± 0.19, and the lowest was -0.01 ± 0.04. Conclusion: The data analyzed showed a good correlation between the measurements made by the coach and trainees, indicating that ultrasound of the quadriceps muscle is a viable and easily applicable tool.


Subject(s)
Humans , Male , Female , Adult , Ultrasonography/methods , Point-of-Care Systems , Quadriceps Muscle/diagnostic imaging , Prospective Studies , Reproducibility of Results , Quadriceps Muscle/physiopathology , Middle Aged
13.
Rev. argent. radiol ; 79(4): 182-191, dic. 2015. ilus, tab
Article in Spanish | LILACS | ID: biblio-843192

ABSTRACT

El desgarro del músculo recto femoral (RF) es el más frecuente dentro del grupo muscular cuadricipital y representa una de las causas más habituales de lesiones musculares del miembro inferior (luego de la injuria del grupo isquiotibial). Dada la complejidad de su anatomía, la sintomatología puede ser poco clara, por lo que los métodos de diagnóstico por imagen y, en especial, la resonancia magnética (RM) aportan información precisa sobre el tipo de desgarro, topografía, extensión y severidad. En el presente artículo, se describe detalladamente la anatomía del RFy su estudio selectivo mediante RM, con aportes técnicos específicos para optimizar este método de estudio. Además, se desarrollan los conceptos actuales del desgarro tendinoso, miotendinoso y el infrecuente desgarro miofascial, aportando datos clave que deben estar contemplados en el informe de RM y que son de suma importancia para el médico traumatólogo.


The tear of the anterior rectus femoris is the most frequent injury of the quadriceps muscle group, and one of the most common causes of lower limb muscle lesions (after the injury of the hamstring muscle group). As its anatomy is complex, and symptoms may be unclear, imaging and in particular, Magnetic Resonance Imaging (MRI) provides precise information on the type of tear, topography, extent, and severity. This article presents a detailed description of the anatomy of the RF and a selective study by MRI, with specific technical inputs to optimise this study method. The current concepts of tendinous, myotendinous, and the infrequent myofascial muscle-tendon tears are also presented, with details of key information that must be contemplated in MRI reports of paramount importance to the traumatology doctor.


Subject(s)
Humans , Femur/anatomy & histology , Femur/injuries , Femur/diagnostic imaging , Magnetic Resonance Spectroscopy , Quadriceps Muscle/anatomy & histology , Quadriceps Muscle/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL